New Punjab Building Rules Amendment 2026: What Changed & What It Means for You

New Punjab Building Rules Amendment 2026: What Changed & What It Means for You

Royals Property Consultant is a trusted name for buying, selling, renting, and investing in residential and commercial properties in Zirakpur, Mohali, Chandigarh, and New Chandigarh.

New Punjab Building Rules Amendment
Punjab Building Rules 2026 Amendment: What Changed & Why It Matters
👑 Royals Property Consultant · RERA PBRERA-CHD04-REA0390
PUNJAB GAZETTE · SEPTEMBER 7, 2026

Punjab Building Rules 2026 Amendment: What Changed & What It Means for You

Based on the Punjab Government Gazette (Extraordinary), published Chandigarh, September 7, 2026
📲 Real estate mein aage rehna hai? Latest GMADA & Tricity property updates seedha WhatsApp par — abhi follow karein.
✅ Follow Channel

Quietly, on September 7, 2026, Punjab rewrote nine parts of its building rulebook — and almost nobody outside government offices has noticed yet. No press conference, no headlines. Just an Extraordinary Gazette notification that changes what you’re legally allowed to build on your own roof, how tall your staircase rules get once your building crosses 21 metres, and how close a tower can sit to a high-tension line. If you’re building, buying, or approving a plan anywhere in Punjab right now, this is the one update you don’t want to hear about secondhand from your architect after your drawings are already rejected.

TL;DR — the 9 changes in one look:
  1. Clear heights now in metric (2290 mm, not 7′-6″)
  2. Group Housing clubhouses need dedicated parking (1 ECS/100 sq.m)
  3. Booth/shop mezzanines: storage-only now
  4. Rooftop solar gets a free 2.4 m height exemption from FAR
  5. Balconies on plots >250 sq.m capped at 2.45 m or half the setback
  6. Rooftop toilets (up to 6 sq.m) are now explicitly allowed
  7. High-tension line clearance rules fully rewritten, with an HVDC table up to 800 kV
  8. Buildings over 21 m: every staircase must now be a fire-exit staircase
  9. New Rule 35-A: lifts/escalators must follow NBC 2016 + certified supervision

The notification is G.S.R.52/P.A.11/1995/Ss.43 and 180/Amd.(9)/2026, dated September 2, 2026, published in the Punjab Government Gazette (Extraordinary) on September 7 — the Punjab Urban Planning and Development Building (Second Amendment) Rules, 2026, amending the 2021 Building Rules. Signed by Vikas Garg, Principal Secretary, Department of Housing and Urban Development, Government of Punjab.

This isn’t a headline-grabbing change, but if you’re building a house, planning a Group Housing project, or buying into one that’s still at the approval stage anywhere in Punjab — including Mohali, Zirakpur and New Chandigarh — several of these changes affect your plans directly. Here’s the full rule-by-rule breakdown, in plain language.

What Actually Changed — Rule by Rule

1. Clear-height rules now in clean metric figures

Wherever the old rules said a minimum clear height of “7′-6″”, the amendment replaces this with “not less than 2290 mm” — across general clear-height notes and stilt-parking entries. The old label “Stilt, if provided (Non-habitable height)” has also been simplified to just “Stilt, if provided.”

2. Clubhouse parking inside Group Housing projects

A club building inside a Group Housing Project must now provide parking at 1 ECS (Equivalent Car Space) per 100 sq. m. of FAR area for that club building specifically — a new proviso added to the parking table.

3. Booths, shops & shop-cum-offices — height and mezzanine rules

Maximum floor-to-floor height for booths, shops and shop-cum-offices is capped at 5.0 metres — except inside shopping malls, standalone commercial buildings, multiplexes, miniplexes and mixed land-use projects, where the cap doesn’t apply. A mezzanine floor inside a booth can now only be used for storage of goods, capped at two-thirds of the booth area, and is excluded from FAR.

4. Rooftop solar panels get an FAR exemption

Rooftop photovoltaic solar installations may now have a clear height of up to 2.4 metres beneath the panels, and this structure is excluded from both building height and FAR calculations — a small but genuinely useful change for anyone planning rooftop solar.

5. Balcony limits on larger plots

For plots above 250 sq. m., balcony projection is now capped at half the required setback depth, or 2.450 m (8′-0″), whichever is less.

6. Rooftop toilets now explicitly permitted

A rooftop toilet up to 6 sq. m. in area and 2.75 m in height is now permitted on the terrace of any building, excluded from both FAR and building-height calculations.

7. High Tension electrical line clearances — Rule 29 fully replaced

Rule 29 has been substituted in full with detailed clearance tables for buildings near HT lines — separate vertical and horizontal clearance norms for lines up to 650V, lines between 650V and 33kV, lines above 33kV, and a dedicated table for HVDC systems ranging from 100 kV (4.6m vertical / 2.9m horizontal) up to 800 kV (12.4m vertical / 10.7m horizontal). Where clearance would otherwise fall short, the conductor must be replaced with Aerial Bunched Cable.

8. Mandatory fire-exit staircases above 21 metres

For any building exceeding 21 metres in height, all required staircases must now be fire-exit staircases — directly relevant to Zirakpur and Mohali’s growing stock of high-rise residential towers.

9. New Rule 35-A — Lifts, escalators & moving walks

A brand-new rule requires all lift, escalator and moving-walk installations to conform to the applicable Lift Acts/Rules and to Part 8 (Building Services), Section 5 of the National Building Code of India, 2016. Installation must be supervised by someone holding a Certificate of Competency from the Chief Electrical Inspector, Punjab. Lifts are now permitted up to terrace level in all categories of buildings.

Quick Reference Table

ChangeOld RuleNew Rule
Clear height7′-6″Not less than 2290 mm
Clubhouse parking (Group Housing)Not specified separately1 ECS per 100 sq.m FAR area
Booth/shop floor-to-floor heightNo general cap statedMax 5.0 m (exemptions apply)
Booth mezzanine useNot restricted to storageStorage only, max 2/3 booth area
Rooftop solar clearanceNot addressedUp to 2.4 m, excluded from FAR/height
Balcony (plots >250 sq.m)Prior Serial II normHalf of setback depth or 2.45 m, whichever less
Rooftop toiletNot addressedUp to 6 sq.m, 2.75 m height, excluded from FAR
HT line clearance (Rule 29)Prior versionFully replaced with detailed voltage-wise tables
Staircases >21m buildingsNot mandatedAll staircases must be fire-exit type
Lifts/escalatorsNo dedicated ruleNew Rule 35-A — NBC 2016 compliance + certified supervision

What This Means in Practice

For Builders & Architects

Several clearances are now defined in clean metric figures rather than feet-inches, which should reduce ambiguity at the plan-approval stage. The rooftop solar and rooftop-toilet exemptions give small, genuinely usable additional headroom without an FAR penalty. The 21m fire-exit-staircase rule and the new lift-installation rule (35-A) add compliance steps for taller residential and mixed-use buildings — expect sanctioning authorities to check these going forward. Group Housing developers should factor in the new clubhouse-specific parking norm when planning amenity blocks.

For Buyers

None of this changes anything about a project you’ve already booked — these rules govern future plan approvals, not existing sanctioned buildings. But if you’re evaluating a project still at the approval or early-construction stage — including high-rises in Zirakpur or Group Housing projects in Mohali and New Chandigarh — it’s reasonable to ask whether its plans reflect the amended rules, particularly around fire-exit staircases and clubhouse parking.

Building your own house or villa on a Punjab plot? These rules affect your sanctioned plan directly — clear heights, balcony limits, rooftop use and (for larger projects) staircase and lift compliance. Talk to Royals before you finalise your building plan.

Frequently Asked Questions

1. What is the Punjab Urban Planning and Development Building (Second Amendment) Rules, 2026?A notification issued September 2, 2026, and published in the Punjab Government Gazette on September 7, 2026, amending the Punjab Urban Planning and Development Building Rules, 2021, across several provisions including clear heights, balconies, rooftop use, HT-line clearances, staircases and lifts.
2. Does this affect buildings I’ve already booked or moved into?No — these rules govern future plan sanctioning, not buildings already approved and constructed under the earlier rules.
3. What changed for rooftop solar panels?Rooftop solar installations can now have up to 2.4 m clear height beneath the panels, excluded from FAR and building-height calculations.
4. What is the new rule for buildings above 21 metres?All required staircases in such buildings must now be fire-exit staircases.
5. Is a rooftop toilet allowed now?Yes — up to 6 sq. m. in area and 2.75 m in height, excluded from FAR and building-height calculations.
6. What is Rule 35-A?A new rule requiring lifts, escalators and moving walks to comply with the National Building Code 2016 and be installed under supervision of someone holding a Certificate of Competency from Punjab’s Chief Electrical Inspector.
7. Did balcony rules change?Yes, for plots above 250 sq. m. — balcony projection is now capped at half the required setback depth or 2.45 m, whichever is less.
8. Who signed this notification?Vikas Garg, Principal Secretary to the Government of Punjab, Department of Housing and Urban Development.

Planning to Build or Buy in Punjab?

Get your building plan or project checked against the latest amended rules before you finalise anything.

💬 Talk to Royals
MV
Manindar Verma
Managing Director, Royals Property Consultant · RERA: PBRERA-CHD04-REA0390
15+ years of ground-level Tricity property and construction experience across Mohali, Zirakpur, Chandigarh, Panchkula and New Chandigarh.
Source: Punjab Government Gazette (Extraordinary), Chandigarh, Monday, September 7, 2026 — Legislative Supplement, Part III, Notification No. G.S.R.52/P.A.11/1995/Ss.43 and 180/Amd.(9)/2026.

Disclaimer: This article summarises a government notification for general information and is not a substitute for the official gazette text or professional architectural/legal advice. Rules can be further amended or clarified by the competent authority. Builders and buyers should verify current requirements with the Department of Housing & Urban Development, Government of Punjab, or a qualified architect before relying on any provision for an actual project.

Punjab building bylaws 2026, Punjab new building rules, Punjab house height rules, Punjab 13 metre building height, Punjab balcony rules 2026, Punjab terrace toilet rules, Punjab FAR rules 2026, Punjab rooftop solar rules, Punjab lift terrace rules, GMADA building rules 2026, Mohali Zirakpur construction rules, Punjab building plan approval